In the maintenance of electroplating processes, electrolysis maintenance is one of the commonly used methods. Mastering comprehensive knowledge of electrolysis maintenance is of great significance for improving the stability of the plating solution and product quality. Here, I would like to share some knowledge about electrolysis in gravure electroplating with the readers.
1. Electrolysis maintenance of nickel plating tank:
1.1 The electrolysis of the nickel tank is low current electrolysis, with a current density between 0.05 and 0.1, and a tank voltage between 0.3 and 1V. The purpose is to remove metal ions that are easily precipitated at high potentials in the nickel plating solution. In terms of gravure nickel plating, the most common impurity is copper ions, as the precipitation overpotential of copper ions is lower than that of nickel. A small cathodic polarization can cause copper ions to deposit, achieving the goal of removal.The patented product of Paituo Company ----External electrolysis equipment for nickel plating,can perform low current electrolysis on the nickel plating solution without interrupting production, achieving the purpose of purifying the plating solution. I recommend it to everyone.

1.2 High current electrolysis of the nickel tank can remove iron ions, but it does not mean that iron ions can be reduced at the cathode. Instead, ferrous ions are oxidized to ferric ions through anodic oxidation, thus precipitating and filtering out under lower pH conditions. This method is similar to adding hydrogen peroxide to the tank. Considering energy consumption and material consumption, high current electrolysis of the nickel tank is rarely used and is unnecessary.
2. Electrolysis maintenance of copper plating tank:
2.1 Electrolysis in the copper tank is rarely used. High current electrolysis merely consumes additives but can easily lead to energy and material waste. Generally, this function can be achieved using oxidants and carbon powder.
2.2 Low current electrolysis in the copper tank, with a current density of 1-3A/dm2, can consume sulfides decomposed from additives, forming cuprous sulfide (a common phenomenon of blackening at low current), which can alleviate the issue of poor adhesion in copper plating! However, adhesion issues are generally suppressed by supplementing additive #1, which is fast and effective. Therefore, low current electrolysis in the copper tank is only suitable for adhesion issues that cannot be adjusted by supplementing additive #1 (for example, when supplementing additive #1 easily leads to copper spots, or when the hardness of the plating layer itself is relatively high).
3. Electrolysis of chromium plating tank:
There are three types of chromium tank electrolysis: increasing trivalent chromium, reducing trivalent chromium, and reducing chloride ions.
3.1 Increasing trivalent chromium uses a large cathode and small anode, at normal temperature, with a current density of 20-30 (low current density, low efficiency, more trivalent chromium produced). This method of increasing trivalent chromium is suitable for opening new tanks. While increasing trivalent chromium, it can also quickly raise the temperature of the plating solution. Generally, alcohol is supplemented in the plating tank to increase trivalent chromium, with accurate quantification and easy calculation (1g of alcohol can increase 1.8g of trivalent chromium).